What the advert says

Quoted word for word from the employer's advert. Where it says nothing, we say so.

Working hours
Not mentioned in the advert
Where you can work from
Assess utility interconnection, on-site generation, and redundancy strategies (N, N+1, 2N) against site conditions and load requirements.
Contract
Not mentioned in the advert
Experience asked for
8+ years of experience in data center electrical engineering, power systems design, or mission-critical electrical systems.
Pay
Competitive compensation

Remote flexibility

Region Restricted

Remote work is allowed, but only for candidates based in Europe.

What the employer says

  • Source listing states candidate location: "Remote - Europe"
  • Job description states: "authorized to work in the country in which they apply an"

What Nomaders makes of it

  • Timezone overlap with the listed area is often expected

The quotes above are the employer's own words; the reading is ours. Always check the original listing and employment terms before working from another country.

Before you apply

Questions worth asking: Nomaders interpretation

  • The advert does not say whether this is employment or a contractor arrangement. Ask, as it affects tax and benefits.

Produced automatically from this advert's text; not reviewed by a person. The employer's own page is the final word.

About the role

About Nebius:

Nebius is leading a new era in cloud infrastructure for the global AI economy. We are building a full-stack AI cloud platform that supports developers and enterprises from data and model training through to production deployment, without the cost and complexity of building large in-house AI/ML infrastructure.

Built by engineers, for engineers. From large-scale GPU orchestration to inference optimization, we own the hard problems across compute, storage, networking and applied AI.

Listed on Nasdaq (NBIS) and headquartered in Amsterdam, we have a global footprint with R&D hubs across Europe, the UK, North America and Israel. Our team of 1,500+ includes hundreds of engineers with deep expertise across hardware, software and AI R&D.

The Infrastructure Acquisition Group

The Infrastructure Acquisition Group secures the land, power, and data center capacity that enables the Nebius AI Cloud. We identify where Nebius should grow next, structure the commercial agreements that make that growth possible, and partner across engineering, energy, finance, legal, and development to bring new AI infrastructure online.

We're a small, founding team building this function from the ground up across the Americas, leading the acquisition of colocation, build-to-suit, powered land, and other strategic infrastructure opportunities as one of the world's fastest-growing AI cloud platforms scales.

Examples of Problems We're Solving

Validate electrical feasibility before commercial commitment. A site or agreement is only as good as its ability to support the power capacity and distribution infrastructure required to run it. You'll lead electrical due diligence, utility interconnection analysis, and equipment feasibility review to inform Go / No-Go decisions before deals close.

Keep electrical design decisions ahead of development. Coordinate with Site Selection, Development, Engineering, and Delivery so power distribution topology, redundancy strategy, and equipment assumptions are validated early enough to protect schedule and budget once construction begins.

Build a repeatable technical evaluation program. Help establish the standards, design criteria, and technical readiness gates that will support electrical engineering review across every AI infrastructure acquisition in the Americas.

About the Role

As an Electrical Engineer, you'll provide the technical electrical engineering perspective across the acquisition and development lifecycle — from initial site and deal evaluation through construction readiness. Working within the Infrastructure Acquisition Group, you'll partner with Site Selection, Technical Due Diligence, Development, Energy, Finance, and Delivery to ensure every project's power distribution, utility interconnection, and equipment assumptions are technically sound before they move forward.

This is a build-phase role on a build-phase team. Many of the technical evaluation standards, design criteria, and readiness gates you'll use are still being written — in some cases, you'll help write them. We're looking for someone who can independently assess complex electrical infrastructure while helping build the systems that make every future evaluation faster, more predictable, and more scalable.

What You'll Own

Lead electrical engineering evaluation of prospective sites, colocation capacity, and build-to-suit opportunities.

Own technical assumptions for power distribution topology, capacity, and equipment strategy feeding the pre-construction risk register.

Assess utility interconnection, on-site generation, and redundancy strategies (N, N+1, 2N) against site conditions and load requirements.

Recommend Go / No-Go input on electrical feasibility as projects advance through key development milestones.

Deliver technically validated electrical scope to the Delivery organization with complete documentation and minimized risk.

Technical Due Diligence & Feasibility

Lead electrical due diligence on prospective sites, existing facilities, and colocation capacity under evaluation.

Evaluate utility capacity, interconnection queue position, substation requirements, and on-site generation/UPS strategy against projected IT load.

Assess electrical equipment availability, lead times (transformers, switchgear, generators), and vendor constraints that could affect schedule or capex.

Requirements

  • ·8+ years of experience in data center electrical engineering, power systems design, or mission-critical electrical systems.
  • ·Experience with medium-voltage distribution, switchgear, UPS systems, generators, and utility interconnection for high-density AI/hyperscale environments.
  • ·Strong understanding of electrical capacity planning, redundancy topology (N, N+1, 2N), equipment selection, and capex trade-offs in data center design.
  • ·Experience evaluating electrical feasibility of sites or facilities prior to commercial commitment.
  • ·Excellent communication and executive presentation skills.

Benefits

  • ·Competitive compensation
  • ·Career growth and learning opportunities
  • ·Flexibility and ownership
  • ·Collaborative and innovative culture
  • ·Opportunity to work on impactful AI projects

How to apply

  1. 1Check the flexibility label above, region restricted, matches where you plan to live and work.
  2. 2Tailor your CV to the role at Nebius, mentioning your remote working experience and working hours (CET ±2).
  3. 3Apply directly on the employer's careers page using the button below. Nomaders never handles your application.

Found 2mo ago. Last checked 17 Nov. Always confirm the details on the original posting, salary and location can change after publication.

Listing sourced from Company boards.

Pay not stated · You'll be taken to the employer's careers page.